Quantity: | |
---|---|
Product Name: | Shell Tube Heat Exchanger | Tube Material: | Stainless Steel 304 , 316l |
---|---|---|---|
Shell Material: | PP, SS304, SS316 | Water Side: | Groud Water, Fresh Water, Drink Water ... |
Capacity: | 35KW | Water Flow: | 6.0m3/h |
Water Cooled Shell And Tube Heat Exchangers / Horizontal Tube Evaporator
Advantages
1. U-tube design allows for differential thermal expansion between the shell and the tube bundle as well as for individual tubes
2. Less costly can floating head or packed floating head designs
3. Capable of withstanding thermal shock applications
4. Bundle can be removed from one end for cleaning or replacement
5. Shell circuit can be inspected and steam or mechanically cleaned
Shell and tube heat exchanger Applications and uses
1.Cooling of hydraulic fluid and oil in engines, transmissions and hydraulic power packs.
2.Heating other mediums, such as water, beverage, orange juice and other steam.
3.They are extensively applied in chemical industrial, petroleum and energy source and etc.
Features of U-tube heat exchanger
1)Simple structure, easy manufacturing
2)Large processing quantity (1-2,000m³/h)
3)Stable and reliable operating state
Strong adaptability (applicable to almost all industries)
4)Adaptability to high temperature and pressure (≤800°C; ≤6.0Mpa)
Features of U-tube heat exchanger
Well suited for serve performance requirements with maximum thermal expansion capability
Each tube can expand and contract independently
Catalogue:
1.0 Refrigeration Ton = 3.5KW
Model | Type | Cooling Capacity | Water Flow | Dimension(MM) | |||||||
KW | M3/H | A | B | C | D | E | F | G | H | ||
WHB-5.0DKG | Single Circuit | 11.6 | 2.0 | 660 | 170 | 90 | 500 | 130 | 400 | 60 | 200 |
WHB-8.0DKG | 18.6 | 3.2 | 950 | 170 | 90 | 790 | 190 | 600 | 60 | 200 | |
WHB-10DKG | 23.2 | 4.0 | 1180 | 170 | 90 | 1020 | 350 | 600 | 60 | 200 | |
WHB-12DKG | 27.9 | 4.8 | 900 | 200 | 90 | 740 | 160 | 600 | 60 | 200 | |
WHB-15DKG | 35.0 | 6.0 | 1110 | 200 | 100 | 940 | 150 | 800 | 60 | 200 | |
WHB-20DKG | 46.5 | 8.0 | 1420 | 200 | 100 | 1250 | 370 | 800 | 60 | 200 | |
WHB-40DKG | 93.0 | 16.0 | 1720 | 250 | 110 | 1540 | 300 | 1200 | 60 | 260 | |
WHB-50DKG | 116.3 | 20.0 | 2120 | 250 | 110 | 1940 | 500 | 1200 | 60 | 260 | |
WHB-80DKG | 186.0 | 32.0 | 2100 | 315 | 120 | 1910 | 350 | 1500 | 60 | 300 | |
WHB-120DKG | 279.1 | 48.0 | 2670 | 315 | 130 | 2460 | 600 | 1800 | 60 | 300 | |
WHB-180DKG | 418.7 | 72.0 | 2520 | 400 | 150 | 2280 | 600 | 1600 | 60 | 400 | |
WHB-220DKG | 511.7 | 88.0 | 3040 | 400 | 150 | 2800 | 650 | 2000 | 60 | 400 | |
WHB-5*2EKG | Double Circuits | 23.2 | 4.0 | 1180 | 170 | 90 | 1020 | 350 | 600 | 60 | 200 |
WHB-8*2EKG | 37.2 | 6.5 | 1180 | 200 | 100 | 1010 | 200 | 800 | 60 | 200 | |
WHB-10*2EKG | 46.5 | 8.0 | 14200 | 200 | 100 | 1250 | 370 | 800 | 60 | 200 | |
WHB-12*2EKG | 56.0 | 9.6 | 1460 | 225 | 100 | 1290 | 250 | 1000 | 60 | 200 | |
WHB-15*2EKG | 70.0 | 12.0 | 1360 | 250 | 100 | 1190 | 200 | 1000 | 60 | 260 | |
WHB-30*2EKG | 140.0 | 24.0 | 2030 | 280 | 110 | 1850 | 500 | 1200 | 60 | 260 | |
WHB-35*2EKG | 163.0 | 28.0 | 2340 | 280 | 120 | 2150 | 500 | 1500 | 60 | 260 | |
WHB-5*3SKG | Triple Circuits | 35.0 | 6.0 | 965 | 225 | 100 | 810 | 200 | 600 | 60 | 200 |
WHB-8*3SKG | 55.8 | 9.6 | 1460 | 225 | 100 | 1300 | 400 | 800 | 60 | 200 | |
WHB-10*3SKG | 69.7 | 12.0 | 1390 | 250 | 100 | 1220 | 200 | 1000 | 60 | 260 | |
WHB-12*3SKG | 83.7 | 14.4 | 1650 | 250 | 110 | 1480 | 420 | 1000 | 60 | 260 | |
WHB-20*3SKG | 139.5 | 24.0 | 2100 | 280 | 110 | 1920 | 550 | 1200 | 60 | 260 | |
WHB-25*3SKG | 174.3 | 30.0 | 2050 | 315 | 120 | 1850 | 350 | 1500 | 60 | 300 | |
WHB-30*3SKG | 209.3 | 36.0 | 2430 | 315 | 120 | 2230 | 550 | 1600 | 60 | 300 | |
Design Working Condition: Chilled water in TEMP.(Ti=12℃), water out TEMP.(Tu=7℃), evaporation TEMP.(To=2℃) |
Applications :
Shell Tube Heat Exchanger using a heat exchanger is that they are often easy to service, particularly with models where a floating tube bundle the tube plates are not welded to the outer shell is available on fixed tube sheet heat exchangers
Product Name: | Shell Tube Heat Exchanger | Tube Material: | Stainless Steel 304 , 316l |
---|---|---|---|
Shell Material: | PP, SS304, SS316 | Water Side: | Groud Water, Fresh Water, Drink Water ... |
Capacity: | 35KW | Water Flow: | 6.0m3/h |
Water Cooled Shell And Tube Heat Exchangers / Horizontal Tube Evaporator
Advantages
1. U-tube design allows for differential thermal expansion between the shell and the tube bundle as well as for individual tubes
2. Less costly can floating head or packed floating head designs
3. Capable of withstanding thermal shock applications
4. Bundle can be removed from one end for cleaning or replacement
5. Shell circuit can be inspected and steam or mechanically cleaned
Shell and tube heat exchanger Applications and uses
1.Cooling of hydraulic fluid and oil in engines, transmissions and hydraulic power packs.
2.Heating other mediums, such as water, beverage, orange juice and other steam.
3.They are extensively applied in chemical industrial, petroleum and energy source and etc.
Features of U-tube heat exchanger
1)Simple structure, easy manufacturing
2)Large processing quantity (1-2,000m³/h)
3)Stable and reliable operating state
Strong adaptability (applicable to almost all industries)
4)Adaptability to high temperature and pressure (≤800°C; ≤6.0Mpa)
Features of U-tube heat exchanger
Well suited for serve performance requirements with maximum thermal expansion capability
Each tube can expand and contract independently
Catalogue:
1.0 Refrigeration Ton = 3.5KW
Model | Type | Cooling Capacity | Water Flow | Dimension(MM) | |||||||
KW | M3/H | A | B | C | D | E | F | G | H | ||
WHB-5.0DKG | Single Circuit | 11.6 | 2.0 | 660 | 170 | 90 | 500 | 130 | 400 | 60 | 200 |
WHB-8.0DKG | 18.6 | 3.2 | 950 | 170 | 90 | 790 | 190 | 600 | 60 | 200 | |
WHB-10DKG | 23.2 | 4.0 | 1180 | 170 | 90 | 1020 | 350 | 600 | 60 | 200 | |
WHB-12DKG | 27.9 | 4.8 | 900 | 200 | 90 | 740 | 160 | 600 | 60 | 200 | |
WHB-15DKG | 35.0 | 6.0 | 1110 | 200 | 100 | 940 | 150 | 800 | 60 | 200 | |
WHB-20DKG | 46.5 | 8.0 | 1420 | 200 | 100 | 1250 | 370 | 800 | 60 | 200 | |
WHB-40DKG | 93.0 | 16.0 | 1720 | 250 | 110 | 1540 | 300 | 1200 | 60 | 260 | |
WHB-50DKG | 116.3 | 20.0 | 2120 | 250 | 110 | 1940 | 500 | 1200 | 60 | 260 | |
WHB-80DKG | 186.0 | 32.0 | 2100 | 315 | 120 | 1910 | 350 | 1500 | 60 | 300 | |
WHB-120DKG | 279.1 | 48.0 | 2670 | 315 | 130 | 2460 | 600 | 1800 | 60 | 300 | |
WHB-180DKG | 418.7 | 72.0 | 2520 | 400 | 150 | 2280 | 600 | 1600 | 60 | 400 | |
WHB-220DKG | 511.7 | 88.0 | 3040 | 400 | 150 | 2800 | 650 | 2000 | 60 | 400 | |
WHB-5*2EKG | Double Circuits | 23.2 | 4.0 | 1180 | 170 | 90 | 1020 | 350 | 600 | 60 | 200 |
WHB-8*2EKG | 37.2 | 6.5 | 1180 | 200 | 100 | 1010 | 200 | 800 | 60 | 200 | |
WHB-10*2EKG | 46.5 | 8.0 | 14200 | 200 | 100 | 1250 | 370 | 800 | 60 | 200 | |
WHB-12*2EKG | 56.0 | 9.6 | 1460 | 225 | 100 | 1290 | 250 | 1000 | 60 | 200 | |
WHB-15*2EKG | 70.0 | 12.0 | 1360 | 250 | 100 | 1190 | 200 | 1000 | 60 | 260 | |
WHB-30*2EKG | 140.0 | 24.0 | 2030 | 280 | 110 | 1850 | 500 | 1200 | 60 | 260 | |
WHB-35*2EKG | 163.0 | 28.0 | 2340 | 280 | 120 | 2150 | 500 | 1500 | 60 | 260 | |
WHB-5*3SKG | Triple Circuits | 35.0 | 6.0 | 965 | 225 | 100 | 810 | 200 | 600 | 60 | 200 |
WHB-8*3SKG | 55.8 | 9.6 | 1460 | 225 | 100 | 1300 | 400 | 800 | 60 | 200 | |
WHB-10*3SKG | 69.7 | 12.0 | 1390 | 250 | 100 | 1220 | 200 | 1000 | 60 | 260 | |
WHB-12*3SKG | 83.7 | 14.4 | 1650 | 250 | 110 | 1480 | 420 | 1000 | 60 | 260 | |
WHB-20*3SKG | 139.5 | 24.0 | 2100 | 280 | 110 | 1920 | 550 | 1200 | 60 | 260 | |
WHB-25*3SKG | 174.3 | 30.0 | 2050 | 315 | 120 | 1850 | 350 | 1500 | 60 | 300 | |
WHB-30*3SKG | 209.3 | 36.0 | 2430 | 315 | 120 | 2230 | 550 | 1600 | 60 | 300 | |
Design Working Condition: Chilled water in TEMP.(Ti=12℃), water out TEMP.(Tu=7℃), evaporation TEMP.(To=2℃) |
Applications :
Shell Tube Heat Exchanger using a heat exchanger is that they are often easy to service, particularly with models where a floating tube bundle the tube plates are not welded to the outer shell is available on fixed tube sheet heat exchangers